FC -- GENERAL INFORMATION
The Brand, full range pressure compensating variable flow control is designed so that the orifice area varies
as the lever is rotated. Fluid travels past the variable orifice, by the compensator spool and then out the
controlled flow port. Therefore the flow out of the CF port is proportional to the orifice area which can
vary from closed to wide open. The sum of the controlled flow and the excess flow equals the inlet flow
and as the controlled flow increases the excess flow decreases. Both outlet flows are pressure compensated
with a spool that maintains a constant flow while adjusting for pressure. Hunting between the compensated
pump and our valve is dampened with a cross hole in the casting. Thus, the outlet flow is smooth and
constant regardless of the pressure on the CF and EX port.
|