| EC20300 -- GENERAL INFORMATION
APPLICATION: The EC20300 conveniently interfaces a PLC or transducer with a proportional solenoid.
DESCRIPTION:
|
![]() |
| EC20300 -- GENERAL SPECIFICATIONS | |
| Voltage Supply | 12-30 VDC |
| PWM Output Current | 2.0 Amps Max Continuous |
| PWM Output Frequency | 107Hz +/- 5 Hertz |
| Environmental Ratings | IP66 / NEMA 4 |
| Operating Temperature | -40°C - 85°C (-40°F - 185°F) |
| Storage Temperature | -40°C - 85°C (-40°F - 185°F) |
| EC20300 -- INPUT SPECIFICATIONS | |
| Potentiometer | |
| Wiper Input Impedance | 10K Ohms |
| Wiper Input range | 0-10V |
| Potentiometer guidelines | |
| Resistance | 2K-10K Ohms |
| Minimum Power rating | 1/8th Watt |
| 0-10 Volt Input | Terminal block 2, Pin 9 |
| Input Impedance | 10K Ohms |
| Step response | Output current will equal:
((Input voltage x 0.1) (max current - min current)) + (min current) For every volt of input, output will change 1/10 its full range. |
| 0-5 Volt Input | Terminal block 2, Pin 10 |
| Input Impedance | 10K Ohms |
| Step response | Output current will equal:
((Input voltage x 0.2) (max current - min current)) + (min current) For every volt of input, output will change 1/5 its full range. |
| 4-20mA Input | Terminal block 2, Pin 11 |
| Input Impedance | 250 Ohms |
| Step response | Output current will equal:
((Input current - 4mA) (0.0625) (max current - min current)) + (min current) For every milliamp of input, output will change 1/16 its full range. |
| Enable Input | When Enable is left open (high) the unit is operational. When the enable line is connected to ground (low) the board output immediately goes to 0 Amps. |
| Input Impedance | Greater than 1M Ohms |
| High state EN pin voltage | 1.04V +/- 0.1V, Reading taken with a 40M Ohm Load |
| Source current while pulled low | 5.11uA |
| Ramping Enable Input | When Enable is left open (high) the unit is operational. When the enable line is connected to ground (low) the board output ramps down to the minimum output setting at the rate set by ramp adjustments. |
| Input Impedance | 5.444K Ohms |
| High state REN pin voltage | 5.98V +/- 0.15V Reading taken with a 40M Ohm Load |
| Source current while pulled low | 5.11uA |
| Solid State Outputs (A & B)
Input Specifications |
A and B outputs are activated by applying power to the A on or the B on inputs located on Terminal Block 2, Pins 4 and 5. |
| Input Impedance | Greater than 20K Ohms |
| Output Off Input Voltage Range | 0.0 – 1.1V |
| Output Undetermined (Unstable) | 1.1 – 6.0V Caution, avoid input voltages that fall within this range. |
| Output On Input Voltage Range | 6.0 – 30V |
| Solid State Outputs (A & B)
Output Specifications |
Terminal block 1, Pin 4 and Pin 5 |
| Switched DC Output Current | 2.5 Amps Max Continuous Each Output (A and B) |
| Switched DC Output Voltage | Voltage Out = Voltage Supply – 0.7 Volts |
| EC20300 -- ADJUSTMENTS | |
| Minimum output or zero setting | Clockwise rotation increases minimum output
0 - 1.5 Amps |
| Maximum output | Clockwise rotation increases maximum output
0.05 - 2 Amps Maximum output will always be 50 mA greater then the minimum output |
| Ramping Down, or Fall Time | Clockwise rotation increases ramp time
0.1 - 12 Seconds |
| Ramping Up, or Rise Time | Clockwise rotation increases ramp time
0.1 - 12 Seconds |
ADJUSTMENT PROCEDURES:
Adjustments are made by turning a trim pot screw. The trimmers are 25 turn, end to end
devices. The trimmers have a built in slip clutches so over rotations do not damage them.
It may be necessary to turn the adjustment screw several turns to observe a change in
output. Start by adjusting the min output, and then adjust the max output to the desired
level. The best way to fine tune adjustments is to observe the function response or speed.
It is important to make adjustments in the following order.
1. Minimum output: Start by setting the master Potentiometer or input signal to zero.
Turn the trimmer clockwise until the function begins to move. Now turn the trimmer
back counter clockwise, one full rotation past the point of any visible movement.
2. Maximum output: Start by setting the master Potentiometer to the 100 position on the
dial. Turn the trim pot counter clockwise to decrease function speed. Turn the trim pot
clockwise to increase function speed. Function maximum speed will be limited to the
max flow capabilities of your hydraulic system. Do not rotate the trim pot past the point
of an observable increase in function speed.
3. Ramp up: This feature changes how quickly the valve can open. Clockwise turns
increase the amount of delay. Counterclockwise turns decrease the amount of delay.
4. Ramp down: This Feature changes how quickly the valve can close. Clockwise turns
increase the amount of delay. Counterclockwise turns decrease the amount of delay. Use
discretion when making this adjustment, this will affect how quickly your function stops.
|
|
| NOTE: Brand Hydraulics recommends a 10 amp fuse be placed within 18 inches of this controls power source. The fuse and power source are customer supplied parts. Also, ensure that all unused wires are capped, and electrically isolated from each other and ground. |
|
[Wiring Diagram] [EC20300 Catalog Download] ["EC20300"] |