| EC20200 -- GENERAL INFORMATION
APPLICATION: Proportionally control the speed of hydraulic motors and cylinders.
DESCRIPTION:
|
![]() |
| EC20200 -- GENERAL SPECIFICATIONS | |
| Voltage Supply | 12-30 VDC |
| PWM Output Current | 2.0 Amps Max Continuous |
| PWM Output Description | PWM , Pulse Width Modulation, 0-100% Duty cycle |
| PWM Output Frequency | 107Hz +/- 5 Hertz |
| Switched DC Output Current | 2.5 Amps Max Continuous Each Output (A and B) |
| Switched DC Output Voltage | Voltage Out = Voltage Supply – 0.7 Volts |
| Environmental Ratings | IP66 / NEMA 4 |
| Operating Temperature | -40°C - 85°C (-40°F - 185°F) |
| Storage Temperature | -40°C - 85°C (-40°F - 185°F) |
![]() |
| EC20200 -- ADJUSTMENTS | |
| Minimum output or zero setting | Clockwise rotation increases minimum output
0 - 1.5 Amps |
| Maximum output | Clockwise rotation increases maximum output
0.05 - 2 Amps Maximum output will always be 50 mA greater then the minimum output |
| Ramping Down, or Fall Time | Clockwise rotation increases ramp time
0.1 - 12 Seconds |
| Ramping Up, or Rise Time | Clockwise rotation increases ramp time
0.1 - 12 Seconds |
ADJUSTMENT PROCEDURES:
Adjustments are made by turning a trim pot screw. The trimmers are 25 turn, end to end
devices. The trimmers have a built in slip clutches so over rotations do not damage them.
It may be necessary to turn the adjustment screw several turns to observe a change in
output. Start by adjusting the min output, and then adjust the max output to the desired
level. The best way to fine tune adjustments is to observe the function response or speed.
It is important to make adjustments in the following order.
1. Minimum output: Start by setting the master Potentiometer or input signal to zero.
Turn the trimmer clockwise until the function begins to move. Now turn the trimmer
back counter clockwise, one full rotation past the point of any visible movement.
2. Maximum output: Start by setting the master Potentiometer to the 100 position on the
dial. Turn the trim pot counter clockwise to decrease function speed. Turn the trim pot
clockwise to increase function speed. Function maximum speed will be limited to the
max flow capabilities of your hydraulic system. Do not rotate the trim pot past the point
of an observable increase in function speed.
3. Ramp up: This feature changes how quickly the valve can open. Clockwise turns
increase the amount of delay. Counterclockwise turns decrease the amount of delay.
4. Ramp down: This Feature changes how quickly the valve can close. Clockwise turns
increase the amount of delay. Counterclockwise turns decrease the amount of delay. Use
discretion when making this adjustment, this will affect how quickly your function stops.
|
|
[Wiring Diagram] [EC20200 Catalog Download] ["EC20200"] |