| EC20100 -- GENERAL INFORMATION
APPLICATION: The EC20100 was designed for material spreading equipment and applications requiring a dual output weatherproof control.
DESCRIPTION:
|
![]() |
| EC20100 -- SPECIFICATIONS | |
| Voltage Supply | 12-26 VDC |
| Maximum Auger Output | 2.0 Amps Continuous |
| Maximum Spinner Output | 2.0 Amps Continuous |
| Output Type | PWM , Pulse Width Modulation, 0-100% Duty cycle |
| Frequency | 107Hz +/- 5 Hertz |
| Minimum Load Resistance | Min. load = Voltage Supply ÷ 2 ,
Example: 6 Ohm minimum load for a system with a 12 VDC supply |
| Maximum Operating Current | 4.076 Amps |
| Total Operating Current No Load | 76 mA |
| Current Draw W/Power Switch Off | 450 uA |
| Environmental Ratings | IP66 / NEMA 4 |
| Operating Temperature | -40°C - 85°C (-40°F - 185°F) |
| Storage Temperature | -40°C - 85°C (-40°F - 185°F) |
| Weight, Fully Assembled | 0.839 kg (1.850 lb.) |
![]() |
| EC20100 -- ADJUSTMENTS | |
| Minimum output or zero setting | Clockwise rotation increases minimum output
0 - 1.1 Amps |
| Maximum output | Clockwise rotation increases maximum output
0.05 - 2 Amps Maximum output will be 50 mA greater then the minimum output |
| Ramping Down, or Fall Time | Clockwise rotation increases ramp time
0.1 - 12 Seconds |
| Ramping Up, or Rise Time | Clockwise rotation increases ramp time
0.1 - 12 Seconds |
| Pass Output | Clockwise rotation increases pass output
0 – 2 Amps |
| Blast Output | Clockwise rotation increases blast output
0 – 2 Amps |
ADJUSTMENT PROCEDURES:
Adjustments are made by turning a trim pot screw. The trimmers are 25 turn, end to end
devices. The trimmers have a built in slip clutches so over rotations do not damage them. It
may be necessary to turn the adjustment screw several turns to observe a change in output.
Start by adjusting the min output, and then adjust the max output to the desired level. The
best way to fine tune adjustments is to observe the function response or speed. It is
important to make adjustments in the following order.
1. Minimum output: Start by setting the master Potentiometer or input signal to zero. Turn
the trimmer clockwise until the function begins to move. Now turn the trimmer back
counter clockwise, one full rotation past the point of any visible movement.
2. Maximum output: Start by setting the master Potentiometer to the 100 position on the
dial. Turn the trim pot counter clockwise to decrease function speed. Turn the trim pot
clockwise to increase function speed. Function maximum speed will be limited to the max
flow capabilities of your hydraulic system. Do not rotate the trim pot past the point of an
observable increase in function speed.
3. Ramp up: This feature changes how quickly the valve can open. Clockwise turns
increase the amount of delay. Counterclockwise turns decrease the amount of delay.
4. Ramp down: This Feature changes how quickly the valve can close. Clockwise turns
increase the amount of delay. Counterclockwise turns decrease the amount of delay. Use
discretion when making this adjustment, this will affect how quickly your function stops.
5. Blast output: Push the Blast button to observe whether or not adjustment is necessary.
Turn the trim pot counter clockwise to decrease function speed. Turn the trim pot clockwise
to increase function speed. Blast output will be limited to the span set by the Min and Max
trimmers. Do not rotate the trim pot past the point of desired function speed.
|
|
[Wiring Diagram] [EC20100 Catalog Download] ["EC20100"] |